Low Carbon House Design | Part 5

Elements of Low Carbon House Design

In this article, we will study the elements of low carbon house including design of windows and skylights, door air-gaps, airtightness, thermal bridging and understanding monthly energy demand profiles.

Windows and skylights

Ultra-efficient triple glazing will be used for windows and skylights in combination with insulated timber frame. According to Passivhaus standard, 1990, the resultant U-value will be 0.8 W/m2K.

Use of LED lights. Making use of day lighting from the roof and the windows. This would help reduce the reliance on artificial lighting. Shutters and louvers can be used to control solar gain and glare. (Halliday, 2008 p. 69)

Door Air-gaps

Loss of energy can be prevented by installing automatic door closers. The inside of the doors can be installed with brush strips to close the air gaps near the flooring. Modern, well-insulated doors can improve comfort levels by decreasing loss of heating and cooling.

Airtightness

It is estimated that up to 15% of energy is wasted to losses through the building fabric. Of those losses, up to 20% energy can be lost through windows and roof, while up to 35% heat energy lost is through air gaps near the doors..

Airtightness

Airtightness. Source: Carbontrust.com

 

To ensure airtightness of the building, wet plaster will be applied to the inside of the wall. This will minimise shrinkage between the wall and the floor. Airtightness tapes and membranes will be used to seal all the corner joints of windows and doors. Airtightness tape will be applied at junctions with plaster. It will make the low carbon house 20 times more airtight as compared to the standard homes built according to the building regulations (Passivhaus, 1990).

Airtightness grommets will be used around cabling and pipework to ensure that there is no leakage of air.


Continue Reading

, , , , , , ,

No Comments

Low Carbon House Design | Active thermal insulation and Roof Design | Part 4

Insulation : Active Thermal Insulation

‘Active thermal insulation’ will be used for achieving the thermal efficiency of the structure.

The technique of Active Thermal Insulation has been invented by Hungary, BT & Sons Ltd. Their technique involves use of the temperature of the soil for thermal insulation. The coils are applied all around the walls of the house. The coil is connected to a soil probe or a soil absorber and the liquid in that flows by using a small (50W – 70W) flow pump. This helps to minimise the heat loss of the building. It also helps to cool the interior of the house in summer and reduces the external heat load in summer. The temperature of the Earth is nearly constant +8 ° C to +12 ° C all year round. This system requires to be used in combination with the heat pump.

 

Active Thermal insulation

Active Thermal insulation.  The picture shows the coil runs all around the walls and the roof and is connected to the ground source heat pump.    Source: activethermalinsulation.com

According to the Passivhaus standard, the building needs to have super insulation with low U-value. The effectiveness of a material as an insulator in buildings is measured with the help of U-value, the lower, the better is the building performance. It is known as thermal transmittance (Shomera House Extensions, 2012).

The major benefit of using ‘Active Thermal Insulation is that same efficiency can be achieving using less thicker walls (Active thermal insulation, 2011) which means more space would be release. In Brighton, the land is expensive and an integrated construction method can be utilised to achieve both energy and space efficiency.

Walling material

Neopor cellular lightweight concrete (CLC) will be used for walls, roof and floor.  The benefits of using CLC blocks are tremendous weight reduction, high thermal insulation, optimum fire rating, substantial material saving (no gravel, little cement, less steel required in structure and foundation, easy to construct and produce, low embodied energy material). CLC blocks are available in a variety of shapes and sizes (Source: Neopor.com).

The Neopor CLC blocks used will be 600mm x 440mm x 250mm. These are lightweight interlocking blocks. The pipe coil is placed in part of the CLC block filled with concrete in a way such that the thicker insulated part of the brick is placed at the interior of the building and the thinner insulated part remains exposed to the exterior with active thermal insulation at work.


Continue Reading

, , , , ,

No Comments

Low Carbon House Design | Climate, Orientation and Building Design | Part 3

How to design a Low Carbon House? | House Design

In this article, we will study the climate of the city, orientation of the structure (Waste House), building design and low energy specifications

Location of Waste House

The Waste House is located in Brighton, a town on the south coast of Great Britain. It is situated in the southeast side of Grand Parade campus of the University of Brighton.The low carbon house project is located in the southeast side of the Grand Parade campus of the University of Brighton.

Brighton and Hove Map. Source: Google Maps

Brighton has a temperate climate characterised by mild, calm weather and is sunny in summer, sea breezes and a healthy, bracing air, which is important to keeping a healthy system and body, of course you also need to have regular checkouts to secure your health, from normal visit to the doctors, to the necessary visit to the dentist every years at clinics like Asecra dentist.

Climate Data

According to the statistics provided by (Climate and temperature, 2012), we have almost 4.8 hours of sunshine per day which equates to 1766 hours of sunshine annually. Storms occurred in the years 1703, 1806, 1824, 1848, 1850, 1896, 1910 and 1987 caused serious damage. Also there have recent storms in December 2013 and February 2014 causing fierce wind and floods (The Guardian on ‘UK storms and flooding’, 2014).

Orientation

Waste house is a two storey house. Achieving energy efficiency is the key objective of the project. One of the most important design considerations is achieving optimum orientation of the building in order to achieving optimum energy efficiency.

The southern wall of the waste house will have windows and roof angled at approximately 35° to help in maximizing the solar gain in winter and take advantage of the elliptical solar path (Halliday, 2008 and Pitts and Lanchashire, 2011). Since, the building lies in the central location of the town, it is surrounded by buildings.


Continue Reading

, , , , ,

No Comments

How to design a 3 bedroom house / apartment? | House Design

Guide to designing a 3 bed apartment/house? | Architectural Design

House Design is one of the most popular subjects in architecture. Whilst it may sound very simple, house design does need some research before an architect can sit down and design. Every person has an ideal image of what kind of house they would like to live in – which is exactly the reason why we have thousands of floor plans online and yet when we sit to design, we create something which is different.

3 bedroom house design

Being able to design like an architect requires you to understand the mindset of the person or family you are designing for.

Again, it is a three step procedure similar to the ones below covered in my previous articles.

House Design | 2 bed apartment/house

House Design | 1 bed apartment/house

House Design | Duplex

Step One:

Conducting live casestudies and doing a literature casestudy.

Live casestudy – it is important to visit various 3 bed properties to get an idea of the number of rooms, sizes of rooms and number of people using that house/apartment.

Following aspects have to be studied whilst conducting a case study:

  • study the circulation,
  • the requirements,
  • calculate the number of people it caters to;
  • calculate the areas of individual spaces such as bedroom, bathroom, Hall, Dining, Kitchen, Utility etc.


Continue Reading

, , , , , ,

No Comments